Class II, Division 1 XP Climate 24,000 BTU/Hr AC

SKU: EP-MS24HP-2-1-X-(I)-216-1Z

Engineered for volatile environments, the XP Climate Control EP-MS24HP-2-1-X-(1)-216-1Z is a 24,000 BTU explosion-proof ductless mini-split heat pump certified for Class II, Division 1 (Groups E, F, G) hazardous locations. Featuring high-efficiency DC inverter technology and anti-corrosive blue-fin protection, it delivers reliable climate control and low-ambient operation for offshore platforms, refineries, and chemical processing facilities. The indoor unit is certified, while the outdoor unit is designed for non-hazardous areas.

Weight 195 lbs
Dimensions 48 × 40 × 45 in
Certification

Class II, Division 1, Groups E, F, and G

Country of Origin 🇺🇸 United States (US)

$16,56000

Shipping Time

4 - 6 Weeks

Need faster options? Contact our Hazardous Areas Experts now for quick alternatives!

Found It Cheaper?

We Match It!
Price Match Guarantee

Need Help?

Speak with a Hazardous Area expert now

Description

Class II Division 1 XP Climate      EP-MS24HP-2-1-X-(1)-216-1Z Explosion Proof Mini Split Heat Pump

The XP Climate Control EP-MS24HP-2-1-X-(1)-216-1Z is an industrial-grade, single-zone ductless mini-split heat pump engineered to deliver 24,000 BTU/h of precision heating and cooling in combustible and hazardous environments. Designed specifically for interior Class II, Division 1 (Groups E, F, and G) installations, this unit provides safe climate management where conductive, explosive, or combustible dusts—such as metal powders, carbon black, coal, and grain dust—are continuously or intermittently present in the air.

Built with G20 DC inverter technology, this unit optimizes energy efficiency (19.0 SEER2 / 11.9 EER2) while maintaining ultra-low frequency torque control and reliable operation down to 0°F in cooling and -13°F in heating modes. Designed for heavy-duty field use, it includes a factory-installed explosion-proof fan motor with overload protection, an integrated A2L leak detection sensor, anti-corrosive blue-fin coils tested for 500 hours of salt spray, and an LCD wireless remote with intuitive modes for seamless climate control in rugged industrial shelters.

Key Features:

✅ Interior Certification: Class II, Division 1, Groups E, F, and G (Certificate of Conformance NEC)
✅ High-Efficiency G20 DC Inverter Technology with Power Factor Correction
✅ 500-Hour Salt Spray Tested Anti-Corrosive Acrylic-Resin Blue Coated Coils (Indoor & Outdoor)
✅ Built-in Wi-Fi Interface & Wired Controller Capability
✅ Factory-Installed Indoor A2L Refrigerant Leak Detection Sensor
✅ Explosion-Proof Motor and Overload Protection Installed
✅ Electric Basepan and Compressor Heaters for Low-Ambient Heating Down to -13°F
✅ Self-Diagnosis, Memory/Power Failure Recovery, and Intelligent Defrosting/Preheating
✅ 6-Speed Crossflow Indoor Fan with Multi-Angle Auto Swing and Dry Anti-Mildew (X-Fan) Mode

📦 Package Options:

🔹 Standard System: Wall-Mounted Indoor Evaporator. Outdoor Condensing (208-230V / 1PH / 60Hz)
🔹 Control Package: Wireless Remote Controller with LCD Display + Optional Wired Wall Controller Interface

XP Climate Control EP-MS24HP-2-1-X-(1)-216-1Z Technical Specifications:

FeatureDetails
Model NumberEP-MS24HP-2-1-X-(1)-216-1Z
Hazardous Certification (Interior)Class II, Division 1, Groups E, F, G
System TypeDuctless Mini Split Heat Pump
Rated Cooling Capacity24,000 BTU/h (Min-Max: 5,800 – 26,270 BTU/h)
Rated Heating Capacity24,000 BTU/h @ 47°F (Min-Max: 5,400 – 26,600 BTU/h)
Low-Temp Heating Performance19,200 BTU/h @ 17°F; 15,700 BTU/h @ 5°F (COP: 1.75 @ 5°F)
Efficiency Ratings19.0 SEER2 / 11.9 EER2 / 8.5 HSPF2
Cooling Operating Range0°F to 118°F
Heating Operating Range-13°F to 75°F
Refrigerant Type & Factory ChargeR32 / 42.3 oz (Pre-charged for 25 ft)
Indoor Leak DetectionFactory-installed A2L leak detection sensor
Indoor Unit Dimensions (W x H x D)49-9/16" x 13-7/64" x 9-11/16"
Indoor Unit Weight (Net / Gross)45.1 lbs / 51.7 lbs
Indoor Airflow (Min - Max)412 – 677 CFM
Indoor Sound Pressure Level36 – 51 dB(A)
Outdoor Unit Dimensions (W x H x D)37-23/32" x 25-63/64" x 15-53/64"
Outdoor Unit Weight (Net / Gross)93.7 lbs / 103.6 lbs
Outdoor Compressor TypeGREE G20 / Single Cylinder / 1-Stage Inverter
Coil ProtectionCopper Tube / Aluminum Fin with Acrylic-Resin Blue Coating
(500-hr salt spray tested)
Power Supply208-230V / 1-Phase / 60Hz (Powered at outdoor unit)
Voltage Operating Range187 VAC – 253 VAC
Rated Current11.0 A (Cooling) / 12.0 A (Heating)
MCA / MOCPMCA: 15 A / MOCP: 20 A
Piping Connections (Liquid - Gas)1/4" Liquid - 1/2" Gas (Flared)
Refrigerant Line Limits10 ft min to 131 ft max length / 82 ft max elevation
Wiring RequirementsMain: Per local code; Interconnecting: 14/4 AWG

Certifications & Compliance:

🔗 NEC Class II, Division 1 (Groups E, F, G)
🔗 Certificate of Conformance to NEC Codes
🔗 ASTM B117 (500-Hour Salt Spray) – Corrosion-resistant acrylic-resin blue fin coating protecting coils
🔗 Low Ambient Protection – Factory-installed compressor and basepan heaters for severe-temperature operation
🔗 Download Datasheet

Applications of XP Climate Control EP-MS24HP-2-1-X-(1)-216-1Z:

🔹 Oil & Gas (Offshore Platforms, Refineries, Fuel Storage, and Metering Shelters)
🔹 Chemical Plants & Agricultural Processing (Grain Elevators, Flour Mills, and Starch Plants)
🔹 Mining & Coal Handling Facilities (Conveyor Sheds, Pulverizing Rooms, and MCC Buildings)
🔹 Labs & Battery Storage Facilities
🔹 Manufacturing (Munitions Plants, Powder Coating, and Metal Dust Fabrication Facilities)

What’s in the Box?

📦 1x Indoor Wall-Mounted Evaporator Unit (Class II, Div 1 Rated)
📦 1x Outdoor Condensing Unit
📦 1x Wireless Remote Controller with LCD Display
📦 1x Factory-Installed A2L Leak Detection Sensor
📦 1x Built-In Explosion-Proof Motor & Overload Assembly
📦 1x Owners & Maintenance Documentation Kit

Ordering & Shipping Details

📦 Lead Time:  4 – 6 weeks
📍 Shipping Terms: Worldwide / Freight Delivery / Dedicated Hazardous Equipment Logistics
💳 Payment Options: Credit Card, Wire Transfer, Net 30 Terms Available Upon Approval

Related Products:

🔗 XP Climate Control C1D2 Wall-Mount Mini Split Systems
🔗 Hazardous Area Explosion-Proof Thermostats & Wired Controllers
🔗 Class I, Division 1 / Division 2 Explosion-Proof Industrial HVAC Units

FAQs:

What hazardous environment is this mini-split certified for?
The indoor evaporator unit is engineered and certified for interior Class II, Division 1, Groups E, F, and G locations, making it safe for atmospheres containing combustible metal dusts, carbon black, coal dust, and grain dust.

Can this system heat and cool in extreme outdoor temperatures?
Yes. The system features low-ambient cooling down to 0°F (-18°C) and heating down to -13°F (-25°C), supported by factory-installed electric baseboard and compressor heaters.

What refrigerant does this system use?
It uses environmentally friendly R32 refrigerant and comes equipped with a factory-installed indoor A2L refrigerant leak detection sensor for added field safety.

How is the unit powered?
The entire system runs on a single-phase 208–230V / 60Hz circuit supplied directly to the outdoor unit (MCA: 15A, MOCP: 20A), with an interconnecting 14/4 AWG cable feeding power and control to the indoor unit.