Description
MadgeTech RHTemp1000IS Intrinsically Safe Humidity and Temperature Data Logger
The RHTemp1000IS is an intrinsically safe, compact humidity and temperature recorder designed for reliable operation in hazardous environments. An intrinsically safe, compact humidity and temperature recorder, the RHTemp1000IS, has been approved by SGS. With an accuracy of 0.5 °C, this instrument can measure and record temperatures between 40 °C and +80 °C (-40 °F and +176 °F). The RHTemp1000IS has a storage capacity of 32,768 time-stamped readings and may be set to begin up to 24 months in advance with advanced programming.
Starting, stopping, and downloading are all made simple with the RHTemp1000IS thanks to its compatibility with MadgeTech 4 Software. Analytical data can be viewed in graphical, tabular, and summary forms as well as in engineering units that can be customized. For Class 1 Division 1, Groups A, B, C, and D, the RHTemp1000IS has been certified as intrinsically safe by SGS, and non-incendive for Class 1 Division 2.
Key Features:
- ✅ Intrinsically Safe Certified: Approved for use in Class I, Division I hazardous locations.
- ✅ Durable Construction: Housed in a 316 Stainless Steel enclosure for maximum durability in harsh conditions.
- ✅ High-Precision Sensors: Features a Resistance Temperature Detector (RTD) sensor and a Capacitive Polymer Humidity Sensor for accurate readings.
- ✅ Fast Response Time: Captures rapid changes in environmental conditions.
- ✅ Rapid Data Download: Transfer a full memory log in approximately one minute.
- ✅ Advanced Software Integration: The MadgeTech software is a powerful, analytic tool, available to download for free. It allows for multiple graph overlays, statistical analysis, digital calibration, lethality equations (F0, PU), mean kinetic temperature calculation, automatic report generation, and full multilingual support.
- ✅ User-Friendly Interface: Software features include zoom in/zoom out, data annotation, Min./Max./Average lines, and direct copy to Excel® functionality.
- ✅ Smart Battery Management: Includes a software battery life indicator and easy identification of low battery voltage, powered by a long-lasting 3.6 V lithium battery.
- ✅ Compliance: CE Compliant with an engraved label for permanent identification.
Package Options:
- 📦 Standard Enclosure: A rugged, intrinsically safe temperature and humidity recorder with a 316 Stainless Steel enclosure.
- 📦 Key Ring Enclosure: Includes all features of the standard model, plus a key ring end cap for enhanced portability and easy attachment.
Specifications:
| Temperature | |
| Temperature Sensor: | Resistance Temperature Detector (RTD) |
| Temperature Range: | -40 °C to +80 °C (-40 °F to +176 °F) |
| Temperature Resolution: | 0.01 °C |
| Temperature Response | t63 – 8 minutes to 63% of change |
| Time in Air: | t90 – 68 minutes to 90% of change |
| Calibrated Accuracy: | ±0.5 °C (0 °C to 55 °C) |
| Humidity | |
| Humidity Sensor: | Capacitive Polymer |
| Humidity Range: | 0 %RH to 100 %RH (non-condensing) |
| Humidity Resolution: | 0.1 %RH |
| Humidity Response | t63 – 30 seconds to 63% of change |
| Time in Air: | t90 – 2 minutes to 90% of change |
| Calibrated Accuracy: | ±3.0 %RH maximum |
| General | |
| Start Modes: | Software programmable immediate start or delay start up to 24 months in advance |
| Real Time Recording: | May be used with PC to monitor and record data in real time |
| Memory: | 16,350 readings per channel |
| Password Protection: | Yes |
| Reading Rate: | 1 reading every second up to 1 reading every 24 hours |
| Calibration: | Digital calibration through software |
| Calibration Date: | Automatically recorded within device |
| Memory Wrap: | Yes |
| Data Format: | Date and time stamped °C, °F, K, °R ; %RH, mg/mL, Dew Point |
| Battery Life: | 2 years typical at 25 °C (15 minute reading rate) |
| Battery Type: | 3.6V lithium battery included, user replaceable |
| Time Accuracy: | ±1 minute/month at 25 °C |
| Required Interface Package: | IFC400 or IFC406 |
| Computer Interface: | USB (interface cable required); 125,000 baud |
| Operating System Compatibility: | Windows XP SP3/Vista/Windows 7/Windows 8 |
| MadgeTech Software Compatibility: | Standard Software version 4.1.0.2 or later |
| Secure Software version 4.1.3.0 or later | |
| Operating Environment: | -40 °C to +80 °C (-40 °F to +176 °F), |
| 0 %RH to 100 %RH (non-condensing) | |
| Dimensions: | 1.7 in x 0.97 in x 0.97 in |
| (42 mm x 24.6 mm x 24.6 mm) | |
| Weight: | 2.3 oz (65 g) |
| Material: | 316 Stainless Steel/PEEK |
| Approvals: | CE; Intrinsically Safe for Class I, Div 1, groups ABCD; |
| Non-incendive for Class I, Division 2, groups ABCD Hazardous (Classified) Locations | |
| BATTERY WARNING: FIRE, EXPLOSION AND SEVERE BURN HAZARD. DO NOT RECHARGE, | |
| DISASSEMBLE, HEAT ABOVE 100 °C (212 °F), INCINERATE, CRUSH, OR EXPOSE CONTENTS | |
| TO WATER |
What’s in the Box?
- 📦 RHTemp1000IS Data Logger
- 📦 3.6 V Lithium Battery
- 📦 Calibration Certificate
Certifications & Compliance:
- 🔗 SGS Certified Intrinsically Safe: Approved for Class 1 Division 1, Groups A, B, C, and D.
- 🔗 SGS Certified Non-Incendive: Approved for Class 1 Division 2 environments.
- 🔗 View Certificate of Compliance
- 🔗 Download Datasheet
- 🔗 Download Product User Guide
Applications:
- 🔹 EtO Sterilization: Monitoring critical temperature and humidity levels during Ethylene Oxide sterilization cycles.
- 🔹 Environmental Studies: Capturing long-term climate data in sensitive or hazardous research locations.
- 🔹 Hostile Environment Monitoring: Ideal for use in chemical plants, refineries, and other industrial settings where explosive atmospheres may be present.
- 🔹 Medical & Pharmaceutical: Ensuring compliance and product integrity in the storage and manufacturing of pharmaceuticals in classified areas. Explore our full range of solutions for the pharmaceutical industry.
Ordering & Shipping Details
Ready to enhance safety and compliance in your facility? Contact our hazardous-area specialists today to discuss your specific application and receive a custom quote for the RHTemp1000IS. We provide expert guidance and worldwide shipping to ensure you get the right equipment, right on time.
Related Products:
- 🔗 MadgeTech Data Loggers: Explore our full range of intrinsically safe data loggers for various applications. CHECK OUT NOW!
FAQs:
What is the typical battery life for the RHTemp1000IS?
The RHTemp1000IS is powered by a 3.6 V lithium battery. The typical battery life is 2 years at 25 °C with a 15-minute reading rate. This can vary depending on the sampling rate, operating temperature, and frequency of data downloads. The MadgeTech 4 software includes a convenient battery life indicator.
Is the MadgeTech 4 software required to operate the data logger?
Yes, the MadgeTech 4 software is necessary for starting, stopping, and downloading data from the RHTemp1000IS. The software is a free download from the manufacturer’s website and provides powerful tools for data analysis, reporting, and device configuration.
What is the difference between Class 1 Division 1 and Division 2 certification?
Class 1, Division 1 locations are areas where flammable gases or vapors are present continuously or intermittently under normal operating conditions. Division 2 locations are areas where these substances are present only in abnormal conditions, such as a container failure. The RHTemp1000IS is certified as Intrinsically Safe for Division 1, offering the highest level of protection, and non-incendive for Division 2.
































What others are saying